C13B CorvetteLocal area network systemFactory acceptance programA total of 10Guilin Lida Communications CorporationFebruary 2014C13B CorvetteLocal area network systemFactory acceptance programFiction: Audit: Sign: Sign: Sign: Approval: Document change logVersion number to modify content describing the modifier the date notesCatalogue1 objective 12 main components 13 Debugging Instrumentation 14 systems specification 15 test methods 45.1 quality 45.2 device dimensions 45.3 Security 45.3.1 electrical installation requirements 45.3.2 insulation resistance 45.4 power supply voltage fluctuation of 55.5 system power 55.6 functional test 55.6.1 LAN internal data exchange and communication 55.6.2 LAN to access the Internet features of 55.7 test 65.7.1 shore connection box 65.7.2 Access 65.7. the 3,000 m Router 65.7. a 4,000 switch 75.7.5 Network Server 75.7.6 UPS power supply 8Appendix 1-10A.1 system diagram 101 prefaceTest manual in accordance with the light frigate C13B of LAN equipment specification developed as the basis for equipment inspection.2 system componentsTable 1, test equipmentSerial number name and model number of the Unit notes1 network Cabinet 7 inch LCD monitor 1 2 opto-electrical Converter 1 single mode3,000 MB Router 1 4 Web server 1 5 1 48 Port Gigabit switch 6 AMP Super five 48 Port patch panel 1 7 3000VA UPS 1 8 folding type 1 mouse and keyboard set 9 AMP network socket 30 10 30 AMP jumper 11 base junction box 2 3 Debugging InstrumentationTable 2, debug using instrumentationName type equipment number effective dateDigital multimeter MY-65 260602-1902 Megger ZC25-3 260601-0804 Resistance tester for AT510PRO 360102-0801 Vernier caliper 0-600mm A3-1965 Intelligent variable frequency power supply AN97003H-3KVA 440203-0202 Agilent network tester FrameScope-Pro (N2620A) 400700-1901 The 400700-1902 4 systems specificationTable 3, appearance qualitySerial number check the technical requirements of the project results1 Eva equipment paint colour RAL7001-qualified2 outside equipment nameplates and tags/screen printing plastic labels-eligible3 external visual inspection of equipment and scratch-free, no paint, the appearance of well-qualified4 cabin equipment film color natural-grey/green devices in conformity5 cabin equipment nameplate and mark steel plate/screen printing-qualified6 the well equipment inspection and scratch-free, no paint, the appearance of well-qualifiedTable 4, equipment sizingSerial number name type maximum overall dimensions (mm) (w x h x d) quantity check results1 network Cabinet 600x950x800 1 2 AMP network socket 30 3 AMP jumper 30 4 shore junction box 2 In table 5, securitySerial number check the technical requirements of the project results1 insulation resistance ≥ 20 m ω 2 chassis and metal contacts electrically qualified3 grounding resistance ≤ 10 m ω Table 6, supply voltage fluctuationsSerial number check the technical requirements of the project results1 power supply adaptive (AC198V~242V) work properly-qualifiedTable 7, system power consumptionSerial number check the technical requirements of the project results1 power consumption ≤ 1000W Table 8, equipment featuresOrdinal survey project technical requirements of inspection resultsInternal data interaction and communication within the LAN 1 LAN computers are available for data interaction and communication 2 LAN to access the Internet features of computers within the LAN can access the external network Internet Table 9, measurement of technical parametersSerial number to check the project type technical requirement checks result notes1 base purchased outside the junction box/optical interface network based on certificate and user manual2 network jack connector RJ45 3,000 MB router network protocols other than PPPoE,DHCP,NAPT,NTP,DDNS to buy based on the certificate and user manualTransfer rate 10M/100M/1000Mbps WAN interface 2 LAN port 3 Other ports, 1 Console interface 4,000 switch is purchased outside the hierarchical three-layer based on the certificate and user manualTransfer rate 10M/100M/1000Mbps Exchange store-forward Backplane bandwidth 240Gbps Packet forwarding rate 72Mpps MAC address table 16K Port number 52 Port Description 48 10/100/1000Base-T Ethernet port1000Base-X Gigabit 4 reuse SF port Control ports, 1 Console port 5 Network Server server type rack purchase based on the certificate and user manualCPU type Intel Xeon E5606 CPU clock speed 2130MHz CPU core quad core Standard CPU number 1 The second level cache 8MB RAM type ECC DDR3 Memory 4GB The hard disk type SATA,2T Optical drive can burn DVD Expansion slot 4 Integrated Dual Gigabit Ethernet network controller card Micrsoft Windows Server 2003, the operating system Red Hat EnterpriseLinux (optional install SUSE Linux Enterprise Server/Turbo Linux Enterprise Server/Novell Netware and VMware ESXI 3.5 embedded hypervisor) 6 3KVA UPS power supply rated power purchases based on the certificate and user manualOutput socket GB 2 Input voltage range 115-300V Input frequency range 40-60Hz Output voltage range 220 (1 ± 2%) v Output frequency range of 50 (1 ± 0.2%) Hz 5 test methods5.1 appearance quality testing standard: System device appearance should be free of rust, mildew, cladding layer peeling off, scratches, burrs, mechanical damage, cracking, blistering, and no apparent deformation phenomena, text signs signs clear, control element and its role should be in safe condition. testing methods: using Visual methods, texture, checked against the appearance requirements.5.2 device dimensions testing standard: dimensioning table 4 for testing standards. testing methods: using Vernier calipers for measuring equipment.5.3 security5.3.1 electrical installation requirements measurement standards: product power, chassis and metal can contact position shall not be charged. system connected to the metal body of the ship, requiring safety grounding, connection resistance shall be less than or equal to 10m. testing methods:The handing method and milliohmmeter test measurement and three-meter measurement.5.3.2 insulation resistance measurement standards: the system's power plug and chassis ambient temperature insulation resistance between exposed metal parts should be greater than or equal to 20M. testing methods:Accuracy using 500V megohmmeter to system level 1 power supply plug (ungrounded side) and both ends of the exposed metal parts (power switch reset the position, but the power plug is not connected to the grid), applied test voltage readings become stable, read the insulation resistance value shall comply with the requirements.5.4 power supply voltage fluctuations measurement standards:AC power AC 198V~242V, 50Hz. testing methods:According to the wiring diagram of the system connected, connected inverter power supply AC 220V,50Hz AC power supply, voltage, which revealed a normal AC voltage is the voltage (AC220V), apply power to the device, led lights, connected to the network server and the monitor, observe the LAN function is normal, if you do not meet the technical requirements, you should check whether the switching power supply with good performance, replacement components should be excluded.5.5 system power consumption measurement standards:System power: 1000W Max. testing methods:Direct readout on the intelligent variable frequency power supply power consumption shall comply with the technical requirements.5.6 functional testingAll parts according to the wiring diagram of the system will be connected as required, after the confirmation power.5.6.1 LAN internal data exchange and communication testing methods:1) by supporting the system wiring diagram connect the device, open the device's power.2) inside the LAN switch connected to a test laptop, Notebook software communicates with the Web server for data communication, send a file to a network server; acceptable criterion:1) notebook can communicate properly with a Web server, and send the file to the network server properly;5.6.2 LAN access Internet functionality testing methods:1) by supporting the system wiring diagram connect the device, open the device's power;2) inside the LAN switch connected to a test laptop, notebook external network access on Internet acceptable criterion:1) notebook to access external Internet properly;5.7 test5.7.1 base junction box measurement standards:Project type technical requirements to check results of the inspection notesBase purchased outside the junction box/optical interface network based on certificate and user manual tests methods and acceptance criteria:1) see shore junction box interface meets the technical requirements for eligibility.5.7.2 network measurement standards:Project type technical requirements to check results of the inspection notesNetwork socket interface RJ45 network socket interface tests methods and acceptance criteria:1) view the network socket, interface meets the technical requirements for eligibility.5.7. the 3,000 m router measurement standards:Project type technical requirements to check results of the inspection notesGigabit router network protocols other than PPPoE,DHCP,NAPT,NTP,DDNS to buy based on the certificate and user manualTransfer rate 10M/100M/1000Mbps WAN interface 2 LAN port 3 Other ports, 1 Console interface tests methods and acceptance criteria:1) "network protocol, transmission rate" for checking the specifications is guaranteed by equipment manufacturers and technical and factory inspection, just check the specifications of their equipment and factory certificate.2) viewing port Gigabit router, "WAN interface, LAN interfaces, other ports" meets the technical requirements for qualified.5.7. a 4,000 switch measurement standards:Project type technical requirements to check results of the inspection notesGigabit switch purchases outside the hierarchical three-layer based on the certificate and user manualTransfer rate 10M/100M/1000Mbps Exchange store-forward Backplane bandwidth 240Gbps Packet forwarding rate 72Mpps MAC address table 16K Port number 52 Port Description 48 10/100/1000Base-T Ethernet port1000Base-X Gigabit 4 reuse SF port Control ports, 1 Console port tests methods and acceptance criteria:1) "application level, transmission rate, Exchange, backplane bandwidth, packet forwarding rate description, port, MAC address table" for checking the specifications is guaranteed by equipment manufacturers and technical and factory inspection, just check the specifications of their equipment and factory certificate.2) viewing port Gigabit switch, "port number, control port" meets the technical requirements for qualified.5.7.5 network servers measurement standards:Project type technical requirements to check results of the inspection notesNetwork Server server type rack purchase based on the certificate and user manualCPU type Intel Xeon E5606 CPU clock speed 2130MHz CPU core quad core Standard CPU number 1 The second level cache 8MB RAM type ECC DDR3 Memory 4GB The hard disk type SATA,2T Optical drive can burn DVD Expansion slot 4 Integrated Dual Gigabit Ethernet network controller card Micrsoft Windows Server 2003, the operating system Red Hat EnterpriseLinux (optional install SUSE Linux Enterprise Server/Turbo Linux Enterprise Server/Novell Netware and VMware ESXI 3.5 embedded hypervisor) tests methods and acceptance criteria:1) "server type, CPU type, CPU clock speed, the number of CPU cores, standard CPU, cache, memory type, memory size, the type of hard drive, optical drive, expansion slot, a network controller" to check the technical specifications is guaranteed by equipment manufacturers and technical and factory inspection, just check the specifications of their equipment and factory certificate.2) see network server "operating system" meets the technical requirements for qualified.5.7.6 UPS power supply measurement standards:Project type technical requirements to check results of the inspection notes3KVA UPS power supply rated power purchases based on the certificate and user manualOutput socket GB 2 Input voltage range 115-300V Input frequency range 40-60Hz Output voltage range 220 (1 ± 2%) v Output frequency range of 50 (1 ± 0.2%) Hz tests methods and acceptance criteria:1) "rated power output socket, input voltage range, output voltage, output, input frequency range frequency range" to check the technical specifications is guaranteed by equipment manufacturers and technical and factory inspection, just check the specifications of their equipment and factory certificate.Participants:Test time:Appendix 1System diagramA.1 system diagram
正在翻譯中..