As indicated previously, the steel-concrete-CFRP system could display several distinct failure modes, including concrete crushing, CFRP debonding, CFRP rupture, flange buckling, web crippling, and shear stud failure. The wooden blocks placed between the flanges at the supports and under loading points prevented web crippling