OIL SYSTEM D/O (3)DESCRIPTION (continued)MAGNETIC CHIP DETECTORSA magnetic chip detector is installed on each of the 6 return lines tothe scavenge pumps. Each chip detector has a magnetic tip to collectparticles and a thread for installation into its housing. The housing isdesigned for the installation of a strainer. When it is installed, the chipdetector is safe with a lockwire. The detectors are used for damagelocation determination after electrical chip detector detection.