Complete 5
9
C13B light frigate
LAN system technical specification
6 pages
Guilin Lida Communication Engineering Co. Ltd in February
2014
directory technology index of
1 introduction 1
2 overview of the 1
3 1
4 3
5 working principle structure characteristics of 4
6 installation and adjustment of the 4
7 interface relationship of 4
8 products notice and maintenance of 6
1 objective
this technical specification is divided into eight parts to tell. The first part introduces the shipboard LAN system (hereinafter referred to as the "system") composition and use; the second part introduces the main technical index of the system;The third part introduces the working principle and features of the system; the fourth part introduces the structure characteristics of the system; the fifth part introduces the methods of system installation and adjustment and the matters needing attention; the sixth part introduces the relationship between internal and external interfaces the interface relationship; the seventh part lists the equipment list and spare parts list of products; the eighth part introduces system maintenance and matters needing attention.
the specifications in combination with the actual situation, describes in detail the working principle, main technical index, system interface and system maintenance and other content, users can work principle of the system and the main technical indicators have a detailed understanding of. Overview of
2
2.1 the composition of the system is mainly composed of connecting front end, core interactive unit and terminal access of three parts.
a) connecting front end: including shore based junction box 2;
b) core interactive unit: including network cabinet 1 sets (including 7 inch liquid crystal display 1, a photoelectric converter 1, Gigabit router 1 Taiwan, Taiwan 1 Taiwan, the network server 48 port Gigabit switch 1, AMP super five 48 patch panel 1 table, folding type mouse and keyboard 1 sets, 3000VA UPS1 table);
c) terminal access: including network socket 30, jumper 30. Equipment for LAN system
2.2 uses
the ship installation,Can let the data interaction through the LAN in the restaurant and its crew room access, computer, and have access to the Internet in the shore under the condition, the computers in the LAN can browse the Internet site through network.
3 specification of
3.1
a technical parameters, shore connection box
interface: network,
b optical fiber interface, network interface interface type:
RJ-45 Ethernet interface standard: IEEE802.3
transmission rate: 10M/100M/1000Mbps
mode: full duplex
c, Gigabit router router router
type: the special network protocol: PPPoE, DHCP, NAPT, NTP, DDNS
transmission rate:10M/100M/1000Mbps
port structure: non modular
WAN interface: 2
3
LAN interface: the other port: 1 Console interface
d, Gigabit switch
product types: intelligent switch application level: three layer
transmission rate: 10M/100M/1000Mbps
exchange: store and forward
backplane bandwidth: 240Gbps
packet forwarding rate: the 72Mpps
MAC address table: 16K
port structure: non modular
port number: 52
port Description: 48 10/100/1000Base-T Ethernet port, 1000Base-X port Gigabit SF
4 multiplexed control port: 1 Port Console
power supply voltage: AC 100-240V,50/60Hz
DC 10.8-13.2V
power: 62W
e, network server
server level: Enterprise Server
server type: frame type
CPU type: Intel Xeon E5606
CPU frequency: 2130MHz
CPU core: four core
standard CPU number: 1 A
maximum CPU number: 2 A
two level cache memory: 8MB
type: ECC DDR3
memory: 4GB
maximum memory: 128GB
hard disk type: SATA, 2T
: CD-ROM recordable DVD
expansion slots: 4
network controller: dual Gigabit Ethernet
power type integrated: the number of Hot Swap Power
power: 1
power: 400w
voltage: 220V
Operating system: Micrsoft Windows Server 2003, Red Hat EnterpriseLinux (SUSE Linux Enterprise Server/Turbo can be installed Linux Enterprise Server/Novell Netware and VMware ESXI 3.5 embedded hypervisor)
f, UPS power supply: 3KVA
rated power output socket: GB: 2
input voltage range: 115-300V
input frequency range: 40-60Hz
output voltage range: 220 (1 + 2%) V
output frequency range: 50 (1 + 0.2%) Hz
g, network cabinet
capacity: 18U
categories: server cabinet
size: 0.6 (wide) x 08 (depth) x 0.95 (high)
color: green ash
standard: meet ANSI/EIA RS-31
materials / Technology: computer equipment SPCC high quality cold-rolled steel sheet for
3.2 function index
internal LAN can interact and communicate data, and can access the external Internet through the network has access to the Internet in the condition of. The working principle of
4
internal LAN computer equipment through the switch can interact and communicate data, NAT address translation function of computer equipment access LAN through a router to provide internal LAN, the private address into the Internet legal address,Users can access to an external Internet.
5 the structure characteristics of
a producing high precision CNC equipment) using network cabinet whole process, high-quality cold-rolled steel plate, the side door can be easily disassembled, sandblasting the surface rust, electrostatic spraying, made three processing, convenient installation and maintenance, reinforcement measures, shockproof and shock performance.
b shore connection box) do three treatment, is convenient for installation and maintenance.
c) AMP network socket screw hole surface not visible, elegant appearance; design of smooth lines, single side removing, does not damage the wall, dustproof door design can prevent dust pollution.
6 installation and adjustment of
6.1 installation and adjustment method of
6.1.1 network cabinet
Network cabinet using desktop installation, can be in the top and bottom line in the cabinet.
6.1.2 shore connection box
interface box adopts embedded installation.
6.1.3 AMP network socket
network socket adopts embedded installation, preferably not more than 100m in the control room cabin and placed network cabinet cable distance.
6.2 installation and adjustment note
a) in the process of installation and debugging, will need to network cabinet is installed in a predetermined position, the external power supply and network cable access to the internal need to straighten out the cable, the installation must be make security and protection work, to ensure that the installation personnel security;
b) in the installation of a network socket,Need to install according to the actual situation;
c) connected to your system, then according to the system diagram to check whether there is leakage connection and take the wrong line, after confirmation, can boot electricity.
7 interface
7.1 interface between
a) relationship between the internal connection between the network cabinet Gigabit router with Gigabit switches adopt category five cable and crystal head, firm connection;
b) is connected between the photoelectric converter and Gigabit router network cabinet adopt category five cable and crystal head, firm connection;
c) the connection between a network server with Gigabit router network cabinet adopt category five cable and crystal head, firm connection;
D) between the 7 inch LCD display and network server network cabinet connection uses the VGA line
e) between folding type mouse and keyboard and network server network cabinet connection uses the PS/2 line
f) network cabinet within 7 inch LCD display, the network server, Gigabit router, Gigabit router, photoelectric converter and UPS power supply using the CEFP82/SA3*1 cable connection. The external interface of the
7.2 relationship of
a) power supply network cabinet and power distribution box is connected with CEFP82/SA3*1.5 cable.
b) connected network cabinet and shore connection box adopt category five cable and crystal head, single mode optical fiber connection.
C) network cabinet and network socket communication connection using five types of cable and crystal head, firm connection.
8 products of complete sets of equipment list
Table 1 ordinal name and type number quantity unit note
1 network cabinet 7 inch liquid crystal display 1
2 photoelectric converter 1 single mode
3 Gigabit router network
4 1 server 1
5 48 port Gigabit switch 1
6 AMP super five 48 mouth distribution frame 1
7 3000VA UPS 1
8 foldable mouse and keyboard 1 sets of
9 AMP network socket 30
10 AMP 30
11 base jumper junction box 2
12 crystal head 100
The 13 parts of 1 sets of
14 appearance and installation dimensions of the 7, English
15 technical specification 7, English
16 instructions for use of the 7
17, English repair instructions in 7 copies, English
18 system wiring diagram of the 7
19, English packing list in 7 copies, English
20 quality certificate in 1 copies, English
21 random data CD 3
Table 2 spare parts list number name and type number quantity unit note
1 with shielding RJ45 crystal head 15
2 connection line (2 with the RJ45 crystal head) 3 meters / 5 root root
9 notice and maintenance
A) check cable connections between devices is correct, cable connection should be no short circuit, open circuit, loosening. Especially the cable cannot network cabinets are short circuit.
b) to prevent fire or electric shock, network cabinet should not be exposed to water or water splashing, do not put liquid or inflammable fragile items, such as vases on the device should not be placed in a class of objects, so as to avoid scratching the cabinet panel.
c) in the network cabinet and ship electric distribution box is connected to the power, if the hand is wet, please use the towel to dry your hands or hand dry, can.
d) of the system are not familiar with the staff, not without the operation of network cabinets, maintenance of internal components,Need by specially trained or have a qualified person to repair equipment repair.
e) when the system stops working, make sure the power cut off all equipment.
正在翻譯中..