The typical I–V characteristics and transient response of the UV photodetector were measured using a HP4155B semiconductor parameter analyzer under dark and with UV illumination at 335 nm. The photo-responsivity of the device was measured by Shimadzu UV–vis 2550 spectrophotometer with a deuterium lamp (190–390nm) and a halogen lamp (280–1100nm).