Bump■ It is forbidden to enter into the automatic equipment operation area through the back door of RGV safety fence or other space. It must enter into through the front door in compliance with the SOP. ■ Prior to the commencement of parameter setting, repairing or maintenance, it is required to turn off the power of robot, release the residual pressure and then enter the operation area for work after confirming from the outside of the operation area that the equipment has stopped with no abnormality and the equipment is immovable affirmatively. ■ There must be conspicuous indicating lamp on the robot. As long as the robot is with energy (no matter the robot is moving), the indicating lamp must be turned on to alert all personnel that such robot is with energy. ■ During operation, it is required to co-work. In case of an emergency and need to stop the robot, the co-operator will be able to instantly press the EMO (Emergency Off) bottom for rescue. ■ At the entrance of the fence must a warning sign be posted and a sensing device be installed as well to detect whether there is any person entering. Before the personnel entering into the area, it must turn off the robot according to the instructions first. In addition, it is forbidden to isolate the sensing device. 7.■ Types of Special Operation■ Proceeding with special operations (hot work, confined-space, and hanging) will not be initiated until the process of application is completed. ■ If the function of the fire-fighting system may be suspended due to false alarm of the fire-fighting system arising from the fabrication or the function of the system is invalid due to the failure of the system itself or external force, the fabrication will not be initiated until the application for disruption of fire-fighting system for general operation is completed. ■ If the disaster detector system is likely to be affected while conducting the organic solvent operation, it is required to apply to the relevant units for the gas detector isolating related operations and certainly complete the prevention of detector system to avoid from the loss of system and equipment crash due to the false alarm of the detector system. In addition, after the completion of the fabrication, it is required to inform the relevant units of restoring the detector system. ■ Upon exchanging the special gas cylinder/SLURRY, there must be two or more persons working together (or accompanied with /supervised by the PSC plant affairs staff) and carry out the operation in accordance with the standard operation procedure. During the operation, the operators must wear the appropriate preventive equipment.■ Be sure to turn off the engines for all vehicles and use the wheel chock when loading and unloading combustible articles. In addition, there must be warning sign posted during operation. Moreover, smoking or naked fire is strictly forbidden.■ Driving forklift is not allowed to exceed the speed limit. Backing and unloading shall appoint personnel to supervise on the site. The height of the loaded object shall not block the sight view during driving to avoid any accident. When driving forklift with goods to downhill, it is required to drive backward to prevent from the car crush. Unless necessary, it is not allowed to drive the forklift with the goods hanged up to the top.III. Other Matters to be Notified: (Description supplemented by the business-handling personnel):