6.2 Voltage Probe MethodThis test employs the voltage probe described in the Section 3.3 and covers from 30 MHz to 470MHz.(1) Setting conditions for specimenThe measurement shall be carried out in the configuration of Table 15 and Fig. 13 in accordancewith the setting conditions in the Section 5.3. In the case where the setting conditions in theSection 5.3.2 cannot be configured for any compelling reason, the measurement shall be carriedout in the configuration which employs the artificial power supply circuit network and the harnessof its lengths mm in accordance with Fig. 14. However, as far as the tests in thissection are concerned, all loads and harnesses which do not affect the operation of subject noisesources shall be removed and actuate only loads which are needed to continuously operatesubject noise sources. As for Fig. 13 and Fig. 14, use the ground plane to provide thegrounding treatment equivalent to vehicle mounted condition.