Since the APC reference threshold voltage or APCVRef defines the desired average
output power, its dynamic range must cover the dynamic range of the average optical
power expected from the TOSA under all conditions. For the maximum average output
power from TOSA, the corresponding VPhoto voltage must be equal to or less than the
maximum value of APCVRef. .