Six. Matters needing attention1, the pressure machine properly grounded, with separate grounding as well;2, the machine is not allowed to correct the mold in operation;3, the hydraulic oil for N46 oil or N46 low coagulation antiwear hydraulic oil, 80~100 wire mesh filter used after the first oil change period not exceeding two months is appropriate, after the oil change once every six months;4, the machine after 200 hours of work should check the oil cleanliness requirements, no smell, in the white paper on a drop of oil, oil of the center point within the black stains, otherwise oil;5, the press must not overload;6, the system, such as accidental leakage, to eliminate the fault should be added enough hydraulic oil;7, often check the pump station, oil tank cleaning, no water, dust, foreign matter into the tank;8, such as the conversion function, the system should be the air within the net can work;9, in the test and work if there is abnormal should be immediately shut down inspection;10, 10 minutes to protect the pressure to allow the buck 2.5Mpa.11 fuel tank capacity 80L