Dear Cathy
Very good for the new solution proposal by Mr. Xubo .
I am very interesting to verify it. I appreciate more if other people found other solution. In my experience each new solution always have a some think good
Luigi work in this week end to modify the fw and I think that Monday early there is a new fw that solve all issue found until now.
I will arrive in Shenzhen 12th September afternoons and is possible discussion with Xie and Xubo in date 13th in order to analysed together the solution and found the best way for rework the 3000 MB2 ADF.
From 19 to 25th I and Xie will stay in Primax for the MB2 PI. Until now after many conference call not have any improvement on the CIS issue from sales Italy people.
The two meters are already available in my bag with one samples of my proposal to rework the MB2 ADF
See you soon
Thank you
Ciao