DIRECTIONS FOR USE
1. Thawed adhesive should be immediately placed on
dispense equipment for use.
2. If the adhesive is transferred to a final dispensing
reservoir, care must be exercised to avoid entrapment of
contaiminants and/or air into the adhesive.
3. Adhesive must be completely used within the products
recommended work life of 18 hours.
4. Silver-resin separation may occur if the adhesive is left
out at 22°C beyond the recommended work life.
5. Apply enough adhesive to achieve a 25 to 50μm
wet bondline thickness, dispensed with approximately 25
to 50% filleting on all sides of the die.
6. Alternate dispense amounts may be used depending on
the application requirements.
7. Star or crossed shaped dispense patterns will yield fewer