1-300 Front Interlock RAP Page 1 of 1
1-300 Front Interlock RAP
Description
Fault Code 1-300 indicates that the IO PWB has detected that the Front Interlock Circuit is open.
Initial Action
.
Refer to BSD 1.3 (1 of 3) and LVPS 3 +24 VDC Wirenet (2 of 3) in the following procedure.
.
Visually inspect the Front Interlock, its actuation mechanism, and open and close the Front Door while inspecting for any obvious cause of failure.
Procedure
Close the Front Door, and PO/PO the Machine.
Fault Code 1-300 is still declared.
.... Unanswered
..Yes ..No...
..
If an intermittent condition is suspected, inspect and reseat connectors J51, J234, J691 and J578. If the fault persists, go to OF2 Intermittent Fault RAP.
Enter DC330 004-300 Front Door Interlock. Observe the state of the Front Door Interlock status indicator on the UI screen. Open and close the Front Door.
The Front Door Interlock status indicator switches L on the UI screen when the Front Doors are closed and switches H when the Front Doors are open.
..Yes ... No.... Unanswered
.. ..
Switch on the Service Switch.
Fault Code 1-300 goes away.
..Yes ... No ....Unanswered
.. ..
Go to 1-309 Service Interlock Open RAP.
+24 VDC is measured between J51-9 on Distribution 1 PWB and GND.
.. ..
..Yes ... No ....Unanswered
Perform the following:
.
Check Fuse F21 on Distribution 1 PWB ( PL 13.3).
.
Go to LVPS 3 +24 VDC Wirenet (2 of 3) . Check for an open/short circuit between J51-9 on Distribution 1 PWB and J234-2A on the Left Front Door Interlock.
.
Go to LVPS 3 +24 VDC RAP.
Perform the following:
.
Close the Left and Right Front Door Interlock. Check for continuity between J234-2A and J691-7 on the Sub Driver PWB. Check for continuity between J691-8 on the Sub Driver PWB and J578-1 on the BGM Driver PWB. If the circuit is bad, replace the Left/Right Door Interlock ( PL 13.1).
.
Close the Left and Right Front Door Interlock. Check for continuity between J234-2A and J691-7 on the Sub Driver PWB. Check for continuity between J691-8 on the Sub Driver PWB and J578-1 on the BGM Driver PWB. If the circuit is bad, replace the Left/Right Door Interlock ( PL 13.1).
.
Replace the Sub Driver PWB ( PL 13.2).
.
Replace the BGM Driver PWB ( PL 9.1). Perform the following:
.
Re-check that the Front Doors positively close and hold the Front Door Interlock.
.
If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP, and include the following checks:
Check Fuse F21 on Distribution 1 PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130405.htm
3/22/2011
1-302 Paper Path Module Interlock Open RAP Page 1 of 1
1-302 Paper Path Module Interlock Open RAP
Description
Fault Code 1-302 indicates that the IO PWB has detected that the Paper Path Module Interlock circuit is open.
Initial Action
.
Refer to BSD 1.3 (3 of 3) in the following procedure.
.
Visually inspect the Paper Path Module Interlock, its actuation mechanism, and open, and close the Paper Path Module while inspecting for any obvious cause of failure.
Procedure
PO/PO the Machine
Fault Code 1-302 is still declared.
.... Unanswered
..Yes ..No...
..
Inspect and reseat connectors J691 and J692 on the Sub Driver PWB, J460 on the IO PWB and FS 11, FS 12 on the Paper Path Module Interlock harness. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. Enter DC330 008-304 Paper Path Module Interlock . The signal switches between H and L when the Paper Path Module is opened and closed.
..Yes ... No.... Unanswered
.. ..
Latch the Paper Path Module.
+24 VDC is measured between J691-14 on the Sub Driver PWB and GND.
....Unanswered
..Yes ..No ...
..
Perform the following:
.
Check F21 on Distribution 1 PWB ( PL 13.3).
.
Go to LVPS 3 +24 VDC RAP.
. Go to BSD 1.3 (3 of 3) and check for an open circuit.
Open the Front Doors. Actuate the Service Interlock.
The Paper Path Module Interlock Sensor state goes L and no longer switches state when the Interlock is opened andclosed.
....Unanswered
..Yes ..No ...
..
Replace the IO PWB ( PL 13.3).
Perform the following:
.
Go to Flag12 in BSD 1.3 (3 of 3). Close/cheat the Interlock. Check for an open circuit.
.
Replace the Paper Path Module Interlock ( PL 9.1).
. Replace the Sub Driver PWB ( PL 13.2). Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130464.htm
3/22/2011
1-303 Output Transport Module Interlock Open RAP Page 1 of 1
1-303 Output Transport Module Interlock Open RAP
Description
Fault Code 1-303 indicates that the IO PWB detected that the Output Transport Module Interlock Circuit is open.
Initial Action
.
Refer to BSD 1.3 (3 of 3) and BSD 10.12 (5 of 6) in the following procedure.
.
Visually inspect the Output Transport Module Interlock and its actuation mechanism. Open and close the Output Transport Module
Interlock while inspecting for any obvious cause of failure.
Procedure
PO/PO the Machine
Fault Code 1-303 is still declared.
..Yes ..No...
.... Unanswered
..
Inspect and reseat connectors J691 on the Sub Driver PWB, J618C on the FLY PWB, J55 on the Distribution 1 PWB and J280 on the Output Transport Module Interlock. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP.
Enter DC330 008-302 Output Transport Module Interlock . Open and close the Output Transport Module Front Door.
The Output Transport Interlock Sensor signal switches between H and L when the Output Transport Module Front Door is opened
and closed.
.. ..
..Yes ... No.... Unanswered
LED CR1 on the FLY PWB is lit.
..Yes ..No ...
....Unanswered
..
+24 VDC is measured between J618C-1 on the FLY C PWB and GND.
..Yes ..No...
.... Unanswered
..
Perform the following:
.
Check Fuse F21 on Distribution 1 PWB ( PL 13.3).
.
Go to LVPS 3 +24 VDC Wirenet. Check for an open circuit between J47-B3 on the Distribution 1 PWB and J618C-1 on the FLY C PWB.
.
Go to LVPS 3 +24 VDC RAP.
Replace the FLY C PWB ( PL 13.2).
Open the Front Doors. Actuate the Service Interlock.
The Output Transport Front Interlock Sensor state goes L and no longer switches state when the Output Transport Front Door is opened and closed.
..
..Yes ..No ...
....Unanswered
Replace the IO PWB ( PL 13.3).
Perform the following:
.
Go to Flag14 in BSD 1.3 (3 of 3). Check for an open circuit.
.
Close/cheat the Output Transport Module Interlock. Check for continuity between J280-A1 and J280-B1 at the Output Transport Module Interlock.
.
Replace the Output Transport Module Interlock ( PL 18.18).
.
Replace the FLY PWB ( PL 13.2).
.
The Output Transport Module Front Interlock is working. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP.
.
Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130511.htm
3/22/2011
1-309 Service Interlock Open RAP Page 1 of 1
1-309 Service Interlock Open RAP
Description
Fault Code 1-309 indicates that the IO PWB detected that the Service Interlock Circuit is open. This fault occurs when it is detected that the
Service Interlock is cheated.
Initial Action
.
Refer to BSD 1.3 (1 of 3), BSD 7.1 (1 of 2), BSD 7.15 (1 of 2), LVPS 3 +5 VDC Wirenet and LVPS 3 +24 VDC Wirenet (2 of 3) in the
following procedure.
.
Visually inspect the Service Interlock and its actuation mechanism, and make sure the switch is open.
Procedure
PO/PO the Machine
Fault Code 1-309 is still declared.
..Yes ..No...
.... Unanswered
..
Inspect and check connectors J51 on the Distribution 1 PWB, J470 and J466 on the IO PWB, FS13 and FS14 and FS15 and FS16 on the Service Interlock for an intermittent short circuit to GND. Enter DC330 004-301 Service Interlock. Observe the state of the Service Interlock Sensor as the Interlock is switched ON and OFF. The Service Interlock Sensor signal switches between H and L when the Service Interlock is switched ON and OFF.
.. ..
..Yes ... No.... Unanswered
Switch ON the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.
Continuity is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched ON.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
Switch OFF the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.
An open circuit is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched OFF.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
+5 VDC is measured between J49-4 on the Distribution 1 PWB and GND.
..Yes ..No ...
....Unanswered
..
Perform the following:
.
Check Fuse F14 on Distribution 1 PWB ( PL 13.3).
.
Go to LVPS 3 +5 VDC Wirenet and check for a short circuit between J49-4 on Distribution 1 PWB and FS16 on the Service Interlock.
.
Go to LVPS 3 +5 VDC RAP.
+24 VDC is measured between J51-7 on the Distribution 1 PWB and GND.
..
..Yes ..No ...
....Unanswered
Perform the following:
.
Check F21 on Distribution 1 PWB ( PL 13.3).
.
Go to LVPS 3 +24 VDC Wirenet (2 of 3) . Check for an open circuit between J51-7 on the Distribution 1 PWB and FS14-COM1 on the Service Interlock.
.
Go to LVPS 3 +24 VDC RAP.
Perform the following:
.
Go to Flag18 on BSD 1.3 (1 of 3). Check for an open circuit.
.
Go to Flag19 in BSD 1.3 (1 of 3). Check for an open circuit.
.
Replace the Service Interlock ( PL 13.1).
.
Replace the Sub Driver PWB ( PL 13.2).
. Replace the IO PWB ( PL 13.3). Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130570.htm
3/22/2011
1-358 Fuser Upper Fan Fail RAP Page 1 of 1
1-358 Fuser Upper Fan Fail RAP
Description
Fault Code 1-358 indicates that the IO PWB detected a Fuser Upper Fan failure.
Initial Action
. Refer to BSD 1.4 (1 of 2) and BSD 1.4 (2 of 2) in the following proced
1 300 前台联锁说唱的 1 页 11 300 前台联锁说唱描述故障代码 1 300 指示 IO PWB 已检测到前台联锁电路是开放。初步行动. 请参阅 BSD 1.3 (1 3) 和 LVPS 3 + 24 伏直流变频器 (2 3) 在下面的过程。. 直观地检查前台联锁,其驱动机制,和打开和关闭前门在检查任何明显失败的原因。程序关闭的大门和陂机器。还宣布故障代码 1 300。....没有答案..是的。哈哈。..如果怀疑是间歇出现的条件,检查并重新拔插接头 J51、 J234、 J691 和 J578。如果故障仍然存在,请转到第 2 间歇性故障说唱。输入 DC330 004 300 前门联锁。观察上 UI 屏幕,前门联锁状态指示灯的状态。打开和关闭前门。前门联锁状态指示器时关闭了大门上 UI 屏幕切换 L 和交换机 H 打开大门时。..是啊...哈哈...没有答案.. ..切换服务交换机上。故障代码 1 300 消失。..是啊...不...没有答案.. ..去 1 309 服务联锁打开说唱。+ 24 伏直流电测量 J51 9 分布 1 印制和 gnd (地) 之间.. ....是啊...不...没有答案执行以下操作:. 检查保险丝 F21 分布 1 印制板 (PL 13.3)。. 去 LVPS 3 + 24 VDC 变频器 (2 3)。检查开/短路 J51 9 分布 1 印制和 J234-2A 上左前门联锁之间。. 去 LVPS 3 + 24 VDC 说唱。执行以下操作:. 关闭的左、 右前门联锁。检查 J234-2A 与 J691-7 子司机印制板上的连续性。检查 J691 8 子司机印制板上与 J578-1 BGM 司机印制板上的连续性。如果电路不好,更换左/右门联锁 (PL 13.1)。. 关闭的左、 右前门联锁。检查 J234-2A 与 J691-7 子司机印制板上的连续性。检查 J691 8 子司机印制板上与 J578-1 BGM 司机印制板上的连续性。如果电路不好,更换左/右门联锁 (PL 13.1)。. 替换子驱动程序 PWB (PL 13.2)。. 替换此 BGM PWB (PL 9.1) 驱动程序。执行以下操作:. 重新检查大门正面地闭上,把前门联锁。. 如果怀疑是间歇出现的条件,转到第 2 间歇性故障说唱,并包括以下检查:检查保险丝 F21 分布 1 印制板 (PL 13.3)。pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130405.htm2011/3/221 302 纸路径模块联锁打开说唱的 1 页 11 302 纸路径模块联锁打开说唱描述故障代码 1 302 指示 IO PWB 检测纸路径模块联锁电路开放。初步行动. 在下面的过程是指 BSD 1.3 (3 3)。. 直观地检查纸路径模块联锁、 驱动机制和开放,和任何明显失败的原因进行巡查时关闭该文件路径模块。Procedure PO/PO the Machine Fault Code 1-302 is still declared. .... Unanswered ..Yes ..No.....Inspect and reseat connectors J691 and J692 on the Sub Driver PWB, J460 on the IO PWB and FS 11, FS 12 on the Paper Path Module Interlock harness. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. Enter DC330 008-304 Paper Path Module Interlock . The signal switches between H and L when the Paper Path Module is opened and closed. ..Yes ... No.... Unanswered .. ..Latch the Paper Path Module. +24 VDC is measured between J691-14 on the Sub Driver PWB and GND. ....Unanswered ..Yes ..No .....Perform the following: . Check F21 on Distribution 1 PWB ( PL 13.3). . Go to LVPS 3 +24 VDC RAP. . Go to BSD 1.3 (3 of 3) and check for an open circuit. Open the Front Doors. Actuate the Service Interlock. The Paper Path Module Interlock Sensor state goes L and no longer switches state when the Interlock is opened andclosed. ....Unanswered ..Yes ..No .....Replace the IO PWB ( PL 13.3). Perform the following: . Go to Flag12 in BSD 1.3 (3 of 3). Close/cheat the Interlock. Check for an open circuit. . Replace the Paper Path Module Interlock ( PL 9.1). . Replace the Sub Driver PWB ( PL 13.2). Replace the IO PWB ( PL 13.3). pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130464.htm 3/22/2011 1-303 Output Transport Module Interlock Open RAP Page 1 of 1 1-303 Output Transport Module Interlock Open RAP 描述故障代码 1-303 表示 IO PWB 检测输出运输模块联锁电路是开放。初步行动. 在下面的过程,请参阅 BSD 1.3 (3 3) 和 BSD 10.12 (5 6)。. 目视检查输出运输模块联锁和及其驱动机制。打开和关闭输出运输模块联锁同时检查任何明显失败的原因。程序陂机器故障代码 1-303 仍然声明。..是的。不好。....没有答案..检查并重新拔插接头 J691 子驱动印刷线路板、 飞印制板上的 J618C、 分布 1 印制板上的 J55 和 J280 上输出运输模块联锁。如果怀疑是间歇出现的条件,去为 2 间歇性故障说唱。输入 DC330 008-302 输出运输模块联锁。打开和关闭输出运输模块前门。输出运输联锁传感器信号 H 和 L 之间切换输出运输模块前面的门被打开时和封闭。.. ....是啊...不好。没有答案点亮 LED CR1 飞印制板上。..是的。不.......没有答案..+ J618C-1 飞 C 印制板上和 gnd (地) 之间测量 24 伏直流电..是的。不好。....没有答案..执行以下操作:. 检查保险丝 F21 分布 1 印制板 (PL 13.3)。. 去 LVPS 3 + 24 VDC 变频器。检查有一个开放的电路之间分布 1 印制板上的通用电气 j47 发动机 B3 和 J618C-1 飞 C 印制板上。. 去 LVPS 3 + 24 VDC 说唱。替换 (PL 13.2) 飞 C 印制线路板。Open the Front Doors. Actuate the Service Interlock. The Output Transport Front Interlock Sensor state goes L and no longer switches state when the Output Transport Front Door is opened and closed. ....Yes ..No .......Unanswered Replace the IO PWB ( PL 13.3). Perform the following: . Go to Flag14 in BSD 1.3 (3 of 3). Check for an open circuit. . Close/cheat the Output Transport Module Interlock. Check for continuity between J280-A1 and J280-B1 at the Output Transport Module Interlock. . Replace the Output Transport Module Interlock ( PL 18.18). . Replace the FLY PWB ( PL 13.2). . The Output Transport Module Front Interlock is working. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. . Replace the IO PWB ( PL 13.3). pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130511.htm 3/22/2011 1-309 Service Interlock Open RAP Page 1 of 1 1-309 Service Interlock Open RAP Description Fault Code 1-309 indicates that the IO PWB detected that the Service Interlock Circuit is open. This fault occurs when it is detected that the Service Interlock is cheated. Initial Action . Refer to BSD 1.3 (1 of 3), BSD 7.1 (1 of 2), BSD 7.15 (1 of 2), LVPS 3 +5 VDC Wirenet and LVPS 3 +24 VDC Wirenet (2 of 3) in the following procedure. . Visually inspect the Service Interlock and its actuation mechanism, and make sure the switch is open. Procedure PO/PO the Machine Fault Code 1-309 is still declared. ..Yes ..No....... Unanswered ..Inspect and check connectors J51 on the Distribution 1 PWB, J470 and J466 on the IO PWB, FS13 and FS14 and FS15 and FS16 on the Service Interlock for an intermittent short circuit to GND. Enter DC330 004-301 Service Interlock. Observe the state of the Service Interlock Sensor as the Interlock is switched ON and OFF. The Service Interlock Sensor signal switches between H and L when the Service Interlock is switched ON and OFF. .. ....Yes ... No.... Unanswered Switch ON the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock. Continuity is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched ON. ..Yes ..No .......Unanswered ..Replace the Service Interlock ( PL 13.1). Switch OFF the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock. An open circuit is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched OFF. ..Yes ..No .......Unanswered ..Replace the Service Interlock ( PL 13.1). +5 VDC is measured between J49-4 on the Distribution 1 PWB and GND. ..Yes ..No .......Unanswered ..Perform the following: . Check Fuse F14 on Distribution 1 PWB ( PL 13.3). . Go to LVPS 3 +5 VDC Wirenet and check for a short circuit between J49-4 on Distribution 1 PWB and FS16 on the Service Interlock. . Go to LVPS 3 +5 VDC RAP. +24 VDC is measured between J51-7 on the Distribution 1 PWB and GND. ....是的。不.......没有答案执行以下操作:. 检查对分布 1 F21 PWB (PL 13.3)。. 去 LVPS 3 + 24 VDC 变频器 (2 3)。检查打开 J51 7 分布 1 印制板上与 FS14 COM1 上服务联锁电路。. 去 LVPS 3 + 24 VDC 说唱。执行以下操作:. 在 BSD 1.3 (1 3) 去标记 18。检查有一个开放的电路。. 转到标记 19 在 BSD 1.3 (1 3)。检查有一个开放的电路。. 更换服务互锁 (PL 13.1)。. 替换子驱动程序 PWB (PL 13.2)。.更换 IO PWB (PL 13.3)。更换 IO PWB (PL 13.3)。pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130570.htm2011/3/221 358 热熔器上部风扇故障说唱的 1 页 11 358 热熔器上部风扇失败说唱描述故障代码 1 358 表示 IO PWB 检测热熔器上部风扇故障。初步行动.在以下过程中引用 BSD 1.4 (1 2) 和 BSD 1.4 (2 2)