Root cause – please elaborate from where the “outer forces” can happen which makes “anode shrapnel out of shape”? is it during your functional testing? Kindly specify from which process?
2. Root cause – for the spring positive pole why does it easily deformed? Why is the spring-back function did not work properly? What is your current inspection control to ensure no deformed spring positive pole will be delivered to CCAC?
3. Corrective action – please elaborate how you will “STRENGTHEN INSPECTION OF SPRING’S POSITIVE POLE” is it the inspection method? The inspection sampling size?
4. Corrective action – what do you mean “DIVIDE TESTING PROCESS INTO TWO STEPS TO AVOID DEFORMATION”? please elaborate what is the current testing process? How it will be divided? Elaborate the From-To of the process improvement
5. Prevent system problem – please elaborate what will be improved on the work instruction? What is missing in the work instruction that needs to be updated?