Exact solution of the temperature ®eld within the concrete is found by integrating concrete material properties, heat generation rate due to hydration, and characteristics of the cooling process. The analytic result is applied to understand reported thermocouple readings in a large concrete footing cooled in a pipe lattice. The model is applicable for establishing technical guideline on heat removal from mass concrete. Possible ways on keeping the temperature low within the concrete are suggested for future practices.