1-300 Front Interlock RAP  Page 1 of 1 1-300 Front Interlock RAP Descr的中文翻譯

1-300 Front Interlock RAP Page 1 o

1-300 Front Interlock RAP Page 1 of 1
1-300 Front Interlock RAP
Description
Fault Code 1-300 indicates that the IO PWB has detected that the Front Interlock Circuit is open.
Initial Action
.
Refer to BSD 1.3 (1 of 3) and LVPS 3 +24 VDC Wirenet (2 of 3) in the following procedure.

.
Visually inspect the Front Interlock, its actuation mechanism, and open and close the Front Door while inspecting for any obvious cause of failure.


Procedure
Close the Front Door, and PO/PO the Machine.
Fault Code 1-300 is still declared.
.... Unanswered
..Yes ..No...
..
If an intermittent condition is suspected, inspect and reseat connectors J51, J234, J691 and J578. If the fault persists, go to OF2 Intermittent Fault RAP.
Enter DC330 004-300 Front Door Interlock. Observe the state of the Front Door Interlock status indicator on the UI screen. Open and close the Front Door.
The Front Door Interlock status indicator switches L on the UI screen when the Front Doors are closed and switches H when the Front Doors are open.
..Yes ... No.... Unanswered
.. ..
Switch on the Service Switch.
Fault Code 1-300 goes away.
..Yes ... No ....Unanswered
.. ..
Go to 1-309 Service Interlock Open RAP.
+24 VDC is measured between J51-9 on Distribution 1 PWB and GND.
.. ..
..Yes ... No ....Unanswered
Perform the following:
.
Check Fuse F21 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +24 VDC Wirenet (2 of 3) . Check for an open/short circuit between J51-9 on Distribution 1 PWB and J234-2A on the Left Front Door Interlock.


.
Go to LVPS 3 +24 VDC RAP.
Perform the following:


.
Close the Left and Right Front Door Interlock. Check for continuity between J234-2A and J691-7 on the Sub Driver PWB. Check for continuity between J691-8 on the Sub Driver PWB and J578-1 on the BGM Driver PWB. If the circuit is bad, replace the Left/Right Door Interlock ( PL 13.1).

.
Close the Left and Right Front Door Interlock. Check for continuity between J234-2A and J691-7 on the Sub Driver PWB. Check for continuity between J691-8 on the Sub Driver PWB and J578-1 on the BGM Driver PWB. If the circuit is bad, replace the Left/Right Door Interlock ( PL 13.1).

.
Replace the Sub Driver PWB ( PL 13.2).


.
Replace the BGM Driver PWB ( PL 9.1). Perform the following:

.
Re-check that the Front Doors positively close and hold the Front Door Interlock.

.
If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP, and include the following checks:



Check Fuse F21 on Distribution 1 PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130405.htm
3/22/2011
1-302 Paper Path Module Interlock Open RAP Page 1 of 1

1-302 Paper Path Module Interlock Open RAP
Description
Fault Code 1-302 indicates that the IO PWB has detected that the Paper Path Module Interlock circuit is open.
Initial Action
.
Refer to BSD 1.3 (3 of 3) in the following procedure.

.
Visually inspect the Paper Path Module Interlock, its actuation mechanism, and open, and close the Paper Path Module while inspecting for any obvious cause of failure.


Procedure
PO/PO the Machine
Fault Code 1-302 is still declared.
.... Unanswered
..Yes ..No...
..
Inspect and reseat connectors J691 and J692 on the Sub Driver PWB, J460 on the IO PWB and FS 11, FS 12 on the Paper Path Module Interlock harness. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. Enter DC330 008-304 Paper Path Module Interlock . The signal switches between H and L when the Paper Path Module is opened and closed.
..Yes ... No.... Unanswered
.. ..
Latch the Paper Path Module.
+24 VDC is measured between J691-14 on the Sub Driver PWB and GND.
....Unanswered
..Yes ..No ...
..
Perform the following:
.
Check F21 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +24 VDC RAP.


. Go to BSD 1.3 (3 of 3) and check for an open circuit.
Open the Front Doors. Actuate the Service Interlock.

The Paper Path Module Interlock Sensor state goes L and no longer switches state when the Interlock is opened andclosed.
....Unanswered
..Yes ..No ...
..
Replace the IO PWB ( PL 13.3).
Perform the following:

.
Go to Flag12 in BSD 1.3 (3 of 3). Close/cheat the Interlock. Check for an open circuit.

.
Replace the Paper Path Module Interlock ( PL 9.1).


. Replace the Sub Driver PWB ( PL 13.2). Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130464.htm
3/22/2011
1-303 Output Transport Module Interlock Open RAP Page 1 of 1

1-303 Output Transport Module Interlock Open RAP
Description
Fault Code 1-303 indicates that the IO PWB detected that the Output Transport Module Interlock Circuit is open.
Initial Action
.
Refer to BSD 1.3 (3 of 3) and BSD 10.12 (5 of 6) in the following procedure.

.
Visually inspect the Output Transport Module Interlock and its actuation mechanism. Open and close the Output Transport Module
Interlock while inspecting for any obvious cause of failure.



Procedure
PO/PO the Machine
Fault Code 1-303 is still declared.
..Yes ..No...
.... Unanswered
..
Inspect and reseat connectors J691 on the Sub Driver PWB, J618C on the FLY PWB, J55 on the Distribution 1 PWB and J280 on the Output Transport Module Interlock. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP.
Enter DC330 008-302 Output Transport Module Interlock . Open and close the Output Transport Module Front Door.
The Output Transport Interlock Sensor signal switches between H and L when the Output Transport Module Front Door is opened
and closed.
.. ..
..Yes ... No.... Unanswered
LED CR1 on the FLY PWB is lit.
..Yes ..No ...
....Unanswered
..
+24 VDC is measured between J618C-1 on the FLY C PWB and GND.
..Yes ..No...
.... Unanswered
..
Perform the following:
.
Check Fuse F21 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +24 VDC Wirenet. Check for an open circuit between J47-B3 on the Distribution 1 PWB and J618C-1 on the FLY C PWB.

.
Go to LVPS 3 +24 VDC RAP.


Replace the FLY C PWB ( PL 13.2).
Open the Front Doors. Actuate the Service Interlock.

The Output Transport Front Interlock Sensor state goes L and no longer switches state when the Output Transport Front Door is opened and closed.
..
..Yes ..No ...
....Unanswered
Replace the IO PWB ( PL 13.3).
Perform the following:

.
Go to Flag14 in BSD 1.3 (3 of 3). Check for an open circuit.

.
Close/cheat the Output Transport Module Interlock. Check for continuity between J280-A1 and J280-B1 at the Output Transport Module Interlock.

.
Replace the Output Transport Module Interlock ( PL 18.18).

.
Replace the FLY PWB ( PL 13.2).


.
The Output Transport Module Front Interlock is working. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP.

.
Replace the IO PWB ( PL 13.3).


pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130511.htm
3/22/2011
1-309 Service Interlock Open RAP Page 1 of 1

1-309 Service Interlock Open RAP
Description
Fault Code 1-309 indicates that the IO PWB detected that the Service Interlock Circuit is open. This fault occurs when it is detected that the
Service Interlock is cheated.

Initial Action
.
Refer to BSD 1.3 (1 of 3), BSD 7.1 (1 of 2), BSD 7.15 (1 of 2), LVPS 3 +5 VDC Wirenet and LVPS 3 +24 VDC Wirenet (2 of 3) in the
following procedure.


.
Visually inspect the Service Interlock and its actuation mechanism, and make sure the switch is open.


Procedure
PO/PO the Machine
Fault Code 1-309 is still declared.
..Yes ..No...
.... Unanswered
..
Inspect and check connectors J51 on the Distribution 1 PWB, J470 and J466 on the IO PWB, FS13 and FS14 and FS15 and FS16 on the Service Interlock for an intermittent short circuit to GND. Enter DC330 004-301 Service Interlock. Observe the state of the Service Interlock Sensor as the Interlock is switched ON and OFF. The Service Interlock Sensor signal switches between H and L when the Service Interlock is switched ON and OFF.
.. ..
..Yes ... No.... Unanswered
Switch ON the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.
Continuity is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched ON.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
Switch OFF the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.

An open circuit is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched OFF.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
+5 VDC is measured between J49-4 on the Distribution 1 PWB and GND.
..Yes ..No ...
....Unanswered
..
Perform the following:
.
Check Fuse F14 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +5 VDC Wirenet and check for a short circuit between J49-4 on Distribution 1 PWB and FS16 on the Service Interlock.

.
Go to LVPS 3 +5 VDC RAP.


+24 VDC is measured between J51-7 on the Distribution 1 PWB and GND.
..
..Yes ..No ...
....Unanswered
Perform the following:
.
Check F21 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +24 VDC Wirenet (2 of 3) . Check for an open circuit between J51-7 on the Distribution 1 PWB and FS14-COM1 on the Service Interlock.


.
Go to LVPS 3 +24 VDC RAP.
Perform the following:


.
Go to Flag18 on BSD 1.3 (1 of 3). Check for an open circuit.

.
Go to Flag19 in BSD 1.3 (1 of 3). Check for an open circuit.

.
Replace the Service Interlock ( PL 13.1).

.
Replace the Sub Driver PWB ( PL 13.2).


. Replace the IO PWB ( PL 13.3). Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130570.htm
3/22/2011
1-358 Fuser Upper Fan Fail RAP Page 1 of 1

1-358 Fuser Upper Fan Fail RAP
Description
Fault Code 1-358 indicates that the IO PWB detected a Fuser Upper Fan failure.
Initial Action
. Refer to BSD 1.4 (1 of 2) and BSD 1.4 (2 of 2) in the following proced
0/5000
原始語言: -
目標語言: -
結果 (中文) 1: [復制]
復制成功!
1 300 前台联锁说唱的 1 页 11 300 前台联锁说唱描述故障代码 1 300 指示 IO PWB 已检测到前台联锁电路是开放。初步行动. 请参阅 BSD 1.3 (1 3) 和 LVPS 3 + 24 伏直流变频器 (2 3) 在下面的过程。. 直观地检查前台联锁,其驱动机制,和打开和关闭前门在检查任何明显失败的原因。程序关闭的大门和陂机器。还宣布故障代码 1 300。....没有答案..是的。哈哈。..如果怀疑是间歇出现的条件,检查并重新拔插接头 J51、 J234、 J691 和 J578。如果故障仍然存在,请转到第 2 间歇性故障说唱。输入 DC330 004 300 前门联锁。观察上 UI 屏幕,前门联锁状态指示灯的状态。打开和关闭前门。前门联锁状态指示器时关闭了大门上 UI 屏幕切换 L 和交换机 H 打开大门时。..是啊...哈哈...没有答案.. ..切换服务交换机上。故障代码 1 300 消失。..是啊...不...没有答案.. ..去 1 309 服务联锁打开说唱。+ 24 伏直流电测量 J51 9 分布 1 印制和 gnd (地) 之间.. ....是啊...不...没有答案执行以下操作:. 检查保险丝 F21 分布 1 印制板 (PL 13.3)。. 去 LVPS 3 + 24 VDC 变频器 (2 3)。检查开/短路 J51 9 分布 1 印制和 J234-2A 上左前门联锁之间。. 去 LVPS 3 + 24 VDC 说唱。执行以下操作:. 关闭的左、 右前门联锁。检查 J234-2A 与 J691-7 子司机印制板上的连续性。检查 J691 8 子司机印制板上与 J578-1 BGM 司机印制板上的连续性。如果电路不好,更换左/右门联锁 (PL 13.1)。. 关闭的左、 右前门联锁。检查 J234-2A 与 J691-7 子司机印制板上的连续性。检查 J691 8 子司机印制板上与 J578-1 BGM 司机印制板上的连续性。如果电路不好,更换左/右门联锁 (PL 13.1)。. 替换子驱动程序 PWB (PL 13.2)。. 替换此 BGM PWB (PL 9.1) 驱动程序。执行以下操作:. 重新检查大门正面地闭上,把前门联锁。. 如果怀疑是间歇出现的条件,转到第 2 间歇性故障说唱,并包括以下检查:检查保险丝 F21 分布 1 印制板 (PL 13.3)。pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130405.htm2011/3/221 302 纸路径模块联锁打开说唱的 1 页 11 302 纸路径模块联锁打开说唱描述故障代码 1 302 指示 IO PWB 检测纸路径模块联锁电路开放。初步行动. 在下面的过程是指 BSD 1.3 (3 3)。. 直观地检查纸路径模块联锁、 驱动机制和开放,和任何明显失败的原因进行巡查时关闭该文件路径模块。Procedure PO/PO the Machine Fault Code 1-302 is still declared. .... Unanswered ..Yes ..No.....Inspect and reseat connectors J691 and J692 on the Sub Driver PWB, J460 on the IO PWB and FS 11, FS 12 on the Paper Path Module Interlock harness. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. Enter DC330 008-304 Paper Path Module Interlock . The signal switches between H and L when the Paper Path Module is opened and closed. ..Yes ... No.... Unanswered .. ..Latch the Paper Path Module. +24 VDC is measured between J691-14 on the Sub Driver PWB and GND. ....Unanswered ..Yes ..No .....Perform the following: . Check F21 on Distribution 1 PWB ( PL 13.3). . Go to LVPS 3 +24 VDC RAP. . Go to BSD 1.3 (3 of 3) and check for an open circuit. Open the Front Doors. Actuate the Service Interlock. The Paper Path Module Interlock Sensor state goes L and no longer switches state when the Interlock is opened andclosed. ....Unanswered ..Yes ..No .....Replace the IO PWB ( PL 13.3). Perform the following: . Go to Flag12 in BSD 1.3 (3 of 3). Close/cheat the Interlock. Check for an open circuit. . Replace the Paper Path Module Interlock ( PL 9.1). . Replace the Sub Driver PWB ( PL 13.2). Replace the IO PWB ( PL 13.3). pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130464.htm 3/22/2011 1-303 Output Transport Module Interlock Open RAP Page 1 of 1 1-303 Output Transport Module Interlock Open RAP Description Fault Code 1-303 indicates that the IO PWB detected that the Output Transport Module Interlock Circuit is open. Initial Action . Refer to BSD 1.3 (3 of 3) and BSD 10.12 (5 of 6) in the following procedure. . Visually inspect the Output Transport Module Interlock and its actuation mechanism. Open and close the Output Transport Module Interlock while inspecting for any obvious cause of failure. Procedure PO/PO the Machine Fault Code 1-303 is still declared. ..Yes ..No....... Unanswered ..Inspect and reseat connectors J691 on the Sub Driver PWB, J618C on the FLY PWB, J55 on the Distribution 1 PWB and J280 on the Output Transport Module Interlock. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. Enter DC330 008-302 Output Transport Module Interlock . Open and close the Output Transport Module Front Door. The Output Transport Interlock Sensor signal switches between H and L when the Output Transport Module Front Door is openedand closed. .. ....Yes ... No.... Unanswered LED CR1 on the FLY PWB is lit. ..Yes ..No .......Unanswered ..+24 VDC is measured between J618C-1 on the FLY C PWB and GND. ..Yes ..No....... Unanswered ..Perform the following: . Check Fuse F21 on Distribution 1 PWB ( PL 13.3). . Go to LVPS 3 +24 VDC Wirenet. Check for an open circuit between J47-B3 on the Distribution 1 PWB and J618C-1 on the FLY C PWB. . Go to LVPS 3 +24 VDC RAP. Replace the FLY C PWB ( PL 13.2). Open the Front Doors. Actuate the Service Interlock. The Output Transport Front Interlock Sensor state goes L and no longer switches state when the Output Transport Front Door is opened and closed. ....Yes ..No .......Unanswered Replace the IO PWB ( PL 13.3). Perform the following: . Go to Flag14 in BSD 1.3 (3 of 3). Check for an open circuit. . Close/cheat the Output Transport Module Interlock. Check for continuity between J280-A1 and J280-B1 at the Output Transport Module Interlock. . Replace the Output Transport Module Interlock ( PL 18.18). . Replace the FLY PWB ( PL 13.2). . The Output Transport Module Front Interlock is working. If an intermittent condition is suspected, go to OF2 Intermittent Fault RAP. . Replace the IO PWB ( PL 13.3). pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130511.htm 3/22/2011 1-309 Service Interlock Open RAP Page 1 of 1 1-309 Service Interlock Open RAP Description Fault Code 1-309 indicates that the IO PWB detected that the Service Interlock Circuit is open. This fault occurs when it is detected that the Service Interlock is cheated. Initial Action . Refer to BSD 1.3 (1 of 3), BSD 7.1 (1 of 2), BSD 7.15 (1 of 2), LVPS 3 +5 VDC Wirenet and LVPS 3 +24 VDC Wirenet (2 of 3) in the following procedure. . Visually inspect the Service Interlock and its actuation mechanism, and make sure the switch is open. Procedure PO/PO the Machine Fault Code 1-309 is still declared. ..Yes ..No...
.... Unanswered
..
Inspect and check connectors J51 on the Distribution 1 PWB, J470 and J466 on the IO PWB, FS13 and FS14 and FS15 and FS16 on the Service Interlock for an intermittent short circuit to GND. Enter DC330 004-301 Service Interlock. Observe the state of the Service Interlock Sensor as the Interlock is switched ON and OFF. The Service Interlock Sensor signal switches between H and L when the Service Interlock is switched ON and OFF.
.. ..
..Yes ... No.... Unanswered
Switch ON the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.
Continuity is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched ON.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
Switch OFF the Service Interlock. Check for continuity between FS15 and FS16 on the Service Interlock.

An open circuit is measured between FS15 and FS16 on the Service Interlock when the Service Interlock is switched OFF.
..Yes ..No ...
....Unanswered
..
Replace the Service Interlock ( PL 13.1).
+5 VDC is measured between J49-4 on the Distribution 1 PWB and GND.
..Yes ..No ...
....Unanswered
..
Perform the following:
.
Check Fuse F14 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +5 VDC Wirenet and check for a short circuit between J49-4 on Distribution 1 PWB and FS16 on the Service Interlock.

.
Go to LVPS 3 +5 VDC RAP.


+24 VDC is measured between J51-7 on the Distribution 1 PWB and GND.
..
..Yes ..No ...
....Unanswered
Perform the following:
.
Check F21 on Distribution 1 PWB ( PL 13.3).

.
Go to LVPS 3 +24 VDC Wirenet (2 of 3) . Check for an open circuit between J51-7 on the Distribution 1 PWB and FS14-COM1 on the Service Interlock.


.
Go to LVPS 3 +24 VDC RAP.
Perform the following:


.
Go to Flag18 on BSD 1.3 (1 of 3). Check for an open circuit.

.
Go to Flag19 in BSD 1.3 (1 of 3). Check for an open circuit.

.
Replace the Service Interlock ( PL 13.1).

.
Replace the Sub Driver PWB ( PL 13.2).


. Replace the IO PWB ( PL 13.3). Replace the IO PWB ( PL 13.3).
pws://file/xerox/edoc/dc5000/chtml/svc.malta.0000130570.htm
3/22/2011
1-358 Fuser Upper Fan Fail RAP Page 1 of 1

1-358 Fuser Upper Fan Fail RAP
Description
Fault Code 1-358 indicates that the IO PWB detected a Fuser Upper Fan failure.
Initial Action
. Refer to BSD 1.4 (1 of 2) and BSD 1.4 (2 of 2) in the following proced
正在翻譯中..
結果 (中文) 3:[復制]
復制成功!
前1
1-300联锁1-300头版说唱说唱
1联锁故障代码描述
1-300表明IO板检测到前面的联锁电路开路。初始行为。
指BSD 1.3(1的3)和3个24伏电网运行(2,3)在下面的过程。。目视检查前联锁,其驱动机构,在检查任何明显的失败原因时,打开和关闭前门。程序,关闭前车门,和宝/宝机器。
故障代码1-300还宣布。……回答
..是的..不..
..
如果怀疑是间歇性的条件下,考察和研究连接器J51,j234,j691和J578。如果故障仍然存在,去2间歇性故障的说唱。
进入dc330 004-300前门联锁。观察用户界面屏幕前车门联锁状态指示器的状态。打开和关闭前门。当前门打开时,前门联锁状态指示灯开关在用户界面屏幕上。是的…没有没有答案的在服务开关上的开关。
故障代码1-300消失。
是的…没有……没有答案..
去1-309服务联锁开启说唱。
24 VDC之间测量j51-9分布1 PWB和GND。。..是的…没有……没有答案。
分布1板检查保险丝F21(PL 13.3)。。
去部分3 24伏电网(2 3)。检查开/短路之间分布1 j51-9 PWB和j234-2a在左前门联锁。。
去部分3 24 VDC的说唱。执行下列内容。关闭左、右前车门联锁。检查在副驾驶PWB j234-2a和j691-7之间的连续性。检查对BGM驱动器PWB子司机PWB和j578-1 j691-8之间的连续性。如果电路坏了,请更换左/右门连锁(13.1号)。。关闭左、右前车门联锁。检查在副驾驶PWB j234-2a和j691-7之间的连续性。检查对BGM驱动器PWB子司机PWB和j578-1 j691-8之间的连续性。如果电路坏了,请更换左/右门连锁(13.1号)。。
更换子驱动板(PL 13.2)。。
代替BGM驱动板(PL 9.1)。执行下列内容。请重新检查前门是否正前方,并保持前门联锁。。
如果怀疑是间歇性的条件下,去为间歇性故障的说唱,并包括以下检查:



检查保险丝F21在PWB(PL 13.3)分布1。
PWS:/ /文件/复印/文件/ dc5000 / chtml / svc.malta.0000130405.htm
3 / 22 / 2011
1-302纸张路径模块联锁打开说唱1页1

1-302纸张路径模块联锁打开说唱
描述
故障代码1-302表明IO板检测到纸张路径模块联锁电路开路。初始行为。
指BSD 1.3(3,3)在下面的过程。。
目视检查的文件路径模块联锁,其致动机构,并打开,并关闭该文件路径模块,同时检查任何明显的原因故障。


程序
宝/宝机器
故障代码1-302还宣布。……回答
..是的..不..
..
检查及复位连接器j691和j692在副驾驶上的印刷电路板,IO板和FS 11 j460,12关于文件路径模块联锁线束。如果怀疑是间歇性的条件下,去为间歇性故障的说唱。进入dc330 008-304纸张路径模块联锁。当文件路径模块被打开和关闭时,信号将在小时和升之间切换。是的…没有没有答案的锁存的文件路径模块。
24 VDC之间测量j691-14在副驾驶PWB和GND。。..没有答案..是..是..没有…。
分布1板检查F21(PL 13.3)。。
去部分3 24 VDC的说唱。。去和1.3(3的3)和检查开路。打开前门的。启动服务连锁。

纸路传感器模块的状态去L和联锁不再开关状态时,联锁开启和关闭。……没有答案..是的..没有……
..
取代IO板(PL 13.3)。执行下列内容。
去BSD 1.3标记12(3 3)。关闭/欺骗联锁。打开电路检查。。取代纸路模块连锁(PL 9.1)。。更换子驱动板(PL 13.2)。更换IO板(PL 13.3)。
PWS:/ /文件/复印/文件/ dc5000 / chtml / svc.malta.0000130464.htm
3 / 22 / 2011
1-303输出传输模块联锁打开说唱1页1

1-303输出传输模块联锁打开说唱
描述
故障代码1-303表明IO板检测到输出的传输模块联锁电路开路。初始行为。
指BSD 1.3(3的3)和10.12(5的6),在下面的程序。。
目视检查输出传输模块联锁及其驱动机构。打开和关闭输出传输模块,联锁,同时检查任何明显的故障原因。



程序
宝/宝机器
故障代码1-303还宣布。是..是的..没有..回答
..
检查及复位连接器j691在副驾驶的印制板,对飞板j618c,J55的分布1 PWB和j280对输出传输模块联锁。如果怀疑是间歇性的条件下,去为间歇性故障的说唱。
进入dc330 008-302输出传输模块联锁。打开和关闭输出传输模块前门。当输出传输模块前门开时,输出传输联锁传感器信号开关封闭。。..是的…没有回答
LED CR1的飞板被点燃。
..是的..没有……
的…..回答

24 VDC之间测量j618c-1上飞C PWB和GND。是..是的..没有..没有答案的- ..。
分布1板检查保险丝F21(PL 13.3)。。
去部分24伏电网3。检查断路j47-b3之间的分布1 PWB和j618c-1上飞C板。。
去部分3 24 VDC的说唱。


取代飞C PWB(PL 13.2)。打开前门的。启动服务连锁。输出传输前联锁传感器状态去升,不再开关状态时,输出传输前门打开和关闭。是..是..是..不……回答
取代IO板(PL 13.3)。执行下列内容。
去标记14在BSD 1.3(3的3)。打开电路检查。。关闭/欺骗输出传输模块联锁。检查j280-a1和j280-b1之间的连续性,在输出传输模块联锁。。更换输出传输模块联锁(PL 18.18)。。
取代飞板(PL 13.2)。。
输出传输模块前联锁工作。如果怀疑是间歇性的条件下,去为间歇性故障的说唱。。
取代IO板(PL 13.3)。


PWS:/ /文件/复印/文件/ dc5000 / chtml / svc.malta.0000130511.htm
3 / 22 / 2011
1-309服务联锁打开说唱1页1

1-309服务联锁打开
描述
说唱
正在翻譯中..
 
其它語言
本翻譯工具支援: 世界語, 中文, 丹麥文, 亞塞拜然文, 亞美尼亞文, 伊博文, 俄文, 保加利亞文, 信德文, 偵測語言, 優魯巴文, 克林貢語, 克羅埃西亞文, 冰島文, 加泰羅尼亞文, 加里西亞文, 匈牙利文, 南非柯薩文, 南非祖魯文, 卡納達文, 印尼巽他文, 印尼文, 印度古哈拉地文, 印度文, 吉爾吉斯文, 哈薩克文, 喬治亞文, 土庫曼文, 土耳其文, 塔吉克文, 塞爾維亞文, 夏威夷文, 奇切瓦文, 威爾斯文, 孟加拉文, 宿霧文, 寮文, 尼泊爾文, 巴斯克文, 布爾文, 希伯來文, 希臘文, 帕施圖文, 庫德文, 弗利然文, 德文, 意第緒文, 愛沙尼亞文, 愛爾蘭文, 拉丁文, 拉脫維亞文, 挪威文, 捷克文, 斯洛伐克文, 斯洛維尼亞文, 斯瓦希里文, 旁遮普文, 日文, 歐利亞文 (奧里雅文), 毛利文, 法文, 波士尼亞文, 波斯文, 波蘭文, 泰文, 泰盧固文, 泰米爾文, 海地克里奧文, 烏克蘭文, 烏爾都文, 烏茲別克文, 爪哇文, 瑞典文, 瑟索托文, 白俄羅斯文, 盧安達文, 盧森堡文, 科西嘉文, 立陶宛文, 索馬里文, 紹納文, 維吾爾文, 緬甸文, 繁體中文, 羅馬尼亞文, 義大利文, 芬蘭文, 苗文, 英文, 荷蘭文, 菲律賓文, 葡萄牙文, 蒙古文, 薩摩亞文, 蘇格蘭的蓋爾文, 西班牙文, 豪沙文, 越南文, 錫蘭文, 阿姆哈拉文, 阿拉伯文, 阿爾巴尼亞文, 韃靼文, 韓文, 馬來文, 馬其頓文, 馬拉加斯文, 馬拉地文, 馬拉雅拉姆文, 馬耳他文, 高棉文, 等語言的翻譯.

Copyright ©2024 I Love Translation. All reserved.

E-mail: