when transitioning from the Wait state,the specified Temperature is not reached within the specified time.
NOTE:This Fault may occur when the temperature in the installation envirinment is low(10 degree or lower)
When turning the power OFF,turn OFF the Power Switch first and then the Main Power Switch.
Cause/Action
1.Turn the power OFF and ON.
2.Turn the power OFF and check the following:
Remove the Fuser Assembly.The Drawer Connector between the Fuser Assembly and the Main Unit(P/Dj600)for broken/bent pins,foreign substances,burns.and etc.
The connection between the DJ600-A2/A3 and the MCU PWB J431-10/9 for open circuit,short circuit,and poor contact.
If no problems are found,replace the following parts in sequence:
Fuser Assembly(PL 7.1)
MCU PWB(7525/30/35)(PL 18.2A)
MCU PWB(7545/56)(PL 18.2B)